Dark Light
-23%

6-30V 1-Channel Power Relay Module with Adjustable Timing Cycle


  1. Operating voltage: 6-30V
  2. Time interval:0.1 s (minimum) ~ 999 min (maximum) continuously adjustable.
  3. Trigger Signal Source: High-Level Trigger (3.0 V-24 V)
  4. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A
  5. Optocoupler Isolation.

196.00 256.00

This is a versatile 1-Channel Power Relay Module, suitable for various applications like Home Automation Delay Timer Control. Operating within a range of 6-30V, it features an adjustable timing cycle and a convenient digital LED display. With support for micro USB 5.0V power supply, it offers flexible power options. Its output capability allows control of devices up to DC 30V 5A or AC 220V 5A. From home automation to industrial settings, its wide application range makes it an invaluable tool.


Operation Mode:
  1. P1: Trigger signal, the relay is on “OP” time, and then disconnect; Within the “OP” time, proceed as follows:
  2. P1.1: the signal is triggered again, invalid
  3. P1.2: the signal is triggered again, re-clocking
  4. P1.3: Signal has triggered again, the relay is disconnected, stop the clock;
  5. P-2: Trigger signal, after the “CL” time is off, the “OP” time is on. When the timing is completed, the replay will be disconnected;
  6. P3.1: Trigger signal, after the “OP” time is on, the “CL” time is off, then cycle the above actions. If trigger signal within the loop, the relay will be disconnected and stop the clock. The number of cycles ( “LOP “) can be set.
  7. P3.2: No need to trigger the signal after powering up, the “OP” time is on, the “CL” time is off, then cycle the above actions; The number of cycles ( “LOP “) can be set.
  8. P-4: Signal holding function. If the signal is triggered, timing is cleared, the relay remains on; when the signal disappears, the relay will be off when the “OP” time is over; if another signal is triggered during timing, timing will be cleared.
How to choose the time interval:
parameter Introduction: OP power over time, turn off time CL, LOP cycle times (1-999 times, “—” is unlimited cycle)
1. In the selection of parameter set interface mode, and press the STOP button to select the time.
(1)xxx. if the decimal point is in some place, the time interval is s-1 999 s
(2)xx. x is the decimal place is ten, the time interval is 0.1 s 99.9 s-
(3)x. x. x is the decimal point are all on, the time interval is 1 min-999 min
How to set the parameter:
  1. First, make sure relay operation mode
  2. According to the operating relay mode, the main interface (power module will flash current operating mode; standard mode P1.1, then come into the main interface); long press SET key two seconds and then choose and enter selection interface mode; by pressing UP, DOWN key to choose the mode setting  (P1.1 ~ P4)
  3. After selecting the mode, press short SET to set the corresponding parameter, then the parameter you want to set will flash (OP power in time; CL power off time; LOP cycle times, “—” is unlimited cycle ); by UP, DOWN to set the parameter value, support long press (increase or decrease quickly) and press slightly (increase or decrease of 1 unit); after setting the parameter value by short press the STOP key to choosing decimal place; choose the time interval (corresponding time interval is 0.1 s-999 min); Short press SET to set the current mode next parameter, the process is the same as above
  4. After the setting mode parameter, press and hold the SET button then hold the current configuration mode will flash, then go back to the main interface; define success parameter main interface: when the relay does not work, it will show “000” (no decimal point); the operating state relay, the screen has a decimal point
    Mode Select Interface:
    press and hold the SET key to enter; after setting, long-press the SET button back on the main interface
    Activate Relay Mode:
    1.  ON: PO in power over time, the relay can be connected
    2. OFF: relay is not allowed to connect, when in the off state
    in short main interface press the STOP key to achieve turn ON and OFF, the current state will flash; then back to the main interface
    (this function is a function of a sudden stop, 1 key to turn off the relay)
    Sleep Mode:
    C-P Sleep mode: within 5 minutes, no operation; nixie tube will close auto display, and a function program well
    Note:
    1. Press and holding the STOP button for 2 seconds can achieve change from C-P to O-d; the Current state will flash and then return to the main interface
    2. The relay contact is passive and electricity production; 1 channel has the control function on / off

    Package Includes:

    1 x 6-30V 1-Channel Power Relay Module with Adjustable Timing Cycle
Category: Tag:

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.